IPV Series |
|
|
Solar Inverter with MPPT Controller 1KW-6KW |
|
|
|
|
- |
Pure sine wave Inverter |
|
- |
Built-in MPPT charge controller to enhance overall efficiency |
|
- |
Configurable AC/Solar input priority |
|
- |
Compatible to mains voltage or generator power |
|
- |
Overload and short circuit protection |
|
- |
Smart battery charger design for optimized battery performance |
|
|
|
Specification |
|
|
|
|
|
MODEL |
|
2000W |
MPPT Solar controller function |
|
|
Rated Voltage |
|
24V DC |
Rated Charge current |
|
40A |
Load current |
|
15A |
Input voltage range |
|
15-150V DC |
Max.PV open circuit array voltage |
|
150V DC |
Typical idle consumption |
|
At idle<10mA |
Overload protection(DC load) |
|
2.0*lnom>5s 1.5*lnom>20s 1.25*lnom temperature controlled |
Bulk charge |
|
14.6V(default) |
Floating charge |
|
13.4V(default) |
Equalization charge |
|
14.0V(default) |
Over charge disconnection |
|
14.8V |
Over charge recovery |
|
13.6V |
Over discharge disconnection |
|
10.8V(default) |
Over discharge reconnection |
|
12.3V |
Temperature compensation |
|
-13.2mV/C |
Lead acid battery settings |
|
Adjustable |
NiCad battery settings |
|
Adjustable |
Load control mode |
|
1.Low Voltage Reconnect(LVR):Adjustable 2.Low Voltage Disconnect(LVD):Automatic disconnection |
|
|
3.Reconnection:Includes warning flash before disconnect and reconnection |
Low voltage reconnect |
|
24.0-28.0Vdc |
low voltage disconnect |
|
21-0-22dc |
Ambient temperature |
|
0-40oC(full load ) 40-60oC(de-rating) |
Altitude |
|
Operating5000m,Non-Operating 16000m |
Protection class |
|
IP21 |
Battery temperature sensor |
|
BTS-optional remote battery temperature senser for increased charging precision |
Terminal size(fine/single wire) |
|
#8 AWG |
PV inverter battery priority |
|
|
Input Voltage Waveform |
|
Sinusoidal (utility or generator) |
Nominal Input Voltage |
|
230Vac |
Low Line Disconnect |
|
155Vac±4% |
High Line Diconnect |
|
265Vac±4% |
Max AC Input Voltage |
|
270Vrms |
Nominal Input Frequency |
|
50Hz/ 60Hz (Auto detection) |
Over-Load Protection |
|
Circuit breaker |
Output Short Circuit Protection |
|
Circuit breaker |
Efficiency (Line Mode) |
|
>95% |
Transfer Switch Rating |
|
30A |
Transfer Time(Ac to Dc) |
|
20ms (typical) |
Output Voltage Waveform |
|
Sine wave |
Rated Output Power (W) |
|
2000W |
Power Factor |
|
1 |
Nominal Output Voltage (V) |
|
230Vac |
Output Voltage Regulation |
|
±10%rms |
Nominal Efficiency |
|
>80% |
Bypass |
|
Optional |
AC Charger |
|
Optional |
Charge Current Regulation |
|
±5A |
Battery initial voltage |
|
0-15.7 Vdc /31.4/59.1 Vdc(can operate with 0V battery) |
Communication |
|
RJ11 (Used for factory testing. No customer interface available) |
Safety Certification |
|
CE(EN60950) |
EMI Classification |
|
EN50091-2, CLASS A |
Operating Temperature Range |
|
0oC to 40oC |
Storage temperature |
|
-15oC ~ 60oC |
Operation humidity |
|
5% to 95% |
Audible Noise |
|
60dB max |
Cooling |
|
Forced air, variable speed fan |