PV3500 Series |
|
|
|
|
|
|
|
|
Low Frequency Solar Inverter |
|
|
|
|
|
|
|
- |
Power range 1.25KVA-4KVA |
|
|
- |
12V/24V/48VDC input voltage |
|
|
- |
Powerful Charge Rate Up to 65Amp |
|
|
- |
Inbuilt pure copper transformer |
|
|
- |
Pure sine wave output |
|
|
- |
LED+LCD display |
|
|
|
- |
MPPT solar charge controller 40A 45A 60A |
|
|
- |
MPPT Efficiency max 98% |
|
|
- |
50/60HZ automatic sensing |
|
|
- |
RS232 with free CD |
|
|
|
- |
Battery priority function |
|
|
- |
Automatically send signal to start generator |
|
|
- |
DC Start & Automatic Self-Diagnostic Function |
|
|
- |
High Efficiency Design & “Power Saving Mode” |
|
|
|
to Conserve Energy |
|
|
|
|
|
|
|
|
|
Specification |
|
|
|
|
|
|
|
MODEL |
|
PV35-1250 |
Default Battery System Voltage |
|
12VDC |
INVERTER OUTPUT |
Rated Power |
|
1250VA/1.0KW |
Surge Rating (20ms) |
|
3.OKW |
Capable Of Starting Electric Motor |
|
1HP |
Waveform |
|
Pure sine wave/ same as input (bypass mode) |
Nominal Output Voltage RMS |
|
100V/110V/120VAC 220V/230V/240VAC(+/-10% RMS) |
Output Frequency |
|
50Hz/60Hz +/-0.3 Hz |
Inverter Efficiency(Peak) |
|
>88% |
Line Mode Efficiency |
|
>95% |
Power Factor |
|
0.8 |
Typical Transfer Time |
|
10ms(max) |
INPUT |
Voltage |
|
230VAC |
Selectable Voltage Range |
|
96~132VAC/155~280VAC(For Personal Computers) |
Frequency Range |
|
50Hz/60Hz (Auto sensing) 40-80Hz |
BATTERY |
Minimum Start Voltage |
|
10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, *4 for 48VDC) |
Low Battery Alarm |
|
10.5VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) |
Low Battery Cutoff |
|
10.0VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) |
High Voltage Alarm |
|
16.0VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) |
High Battery Voltage Recover |
|
15.5VDC+/-0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) |
Idle Consumption-Search Mode |
|
<25W when power saver on |
CHARGER |
Output Voltage |
|
Depends on battery type |
Charger AC Input Breaker Rating |
|
10A |
Overcharge Protection S.D. |
|
15.7VDC for 12VDC mode (*2 for 24VDC, *4 for 48VDC) |
Maximum Charge Current |
|
35A |
BTS |
Continuous Output Power |
|
Yes Variances in charging voltage & S.D. voltage base on the battery temperature |
BYPASS & PROTECTION |
Input Voltage Waveform |
|
Sine wave (grid or generator) |
Nominal Input Frequency |
|
50Hz or 60Hz |
Overload Protection (SMPS Load) |
|
Circuit breaker |
Output Short Circuit Protection |
|
Circuit breaker |
Bypass Breaker Rating |
|
10A |
Max Bypass Current |
|
30Amp |
SOLAR |
Maximum PV Charge Current |
|
30A |
DC Voltage |
|
12V/24V atuo work |
Maximum PV Array Power |
|
450W |
MPPT Range @ Operating Voltage(VDC) |
|
16-100VDC for 12V mode,32-100V for 24V mode |
Maximum PV Array Open Circuit Voltage |
|
147VDC |
Maximum Efficiency |
|
>98% |
Standby Power Consumption |
|
<2W |
MECHANICAL SPECIFICATIONS |
Mounting |
|
Wall mount |
Dimensions (W*H*D) |
|
414*575*211mm |
Net Weight (Solar CHG) kg |
|
23.5 |
Shipping Dimensions(W*H*D) |
|
505*701*330mm |
Shipping Weight (Solar CHG) kg |
|
25.5 |
OTHER |
Operation Temperature Range |
|
0oC to 40oC |
Storage Temperature |
|
-15oC to 60oC |
Audible Noise |
|
60dB MAX |
Display |
|
LED+LCD |
Standard Warranty |
|
1 year |