| IPV Series |
|
|
| Solar Inverter with MPPT Controller 1KW-6KW |
| |
|
|
| |
- |
Pure sine wave Inverter |
| |
- |
Built-in MPPT charge controller to enhance overall efficiency |
| |
- |
Configurable AC/Solar input priority |
| |
- |
Compatible to mains voltage or generator power |
| |
- |
Overload and short circuit protection |
| |
- |
Smart battery charger design for optimized battery performance |
| |
|
|
| Specification |
|
|
| |
|
|
| MODEL |
|
1500W |
| MPPT Solar controller function |
|
|
| Rated Voltage |
|
24V DC |
| Rated Charge current |
|
40A |
| Load current |
|
15A |
| Input voltage range |
|
15-150V DC |
| Max.PV open circuit array voltage |
|
150V DC |
| Typical idle consumption |
|
At idle<10mA |
| Overload protection(DC load) |
|
2.0*lnom>5s 1.5*lnom>20s 1.25*lnom temperature controlled |
| Bulk charge |
|
14.6V(default) |
| Floating charge |
|
13.4V(default) |
| Equalization charge |
|
14.0V(default) |
| Over charge disconnection |
|
14.8V |
| Over charge recovery |
|
13.6V |
| Over discharge disconnection |
|
10.8V(default) |
| Over discharge reconnection |
|
12.3V |
| Temperature compensation |
|
-13.2mV/C |
| Lead acid battery settings |
|
Adjustable |
| NiCad battery settings |
|
Adjustable |
| Load control mode |
|
1.Low Voltage Reconnect(LVR):Adjustable 2.Low Voltage Disconnect(LVD):Automatic disconnection |
| |
|
3.Reconnection:Includes warning flash before disconnect and reconnection |
| Low voltage reconnect |
|
12.0-14.0Vdc |
| low voltage disconnect |
|
10.5-11Vdc |
| Ambient temperature |
|
0-40oC(full load ) 40-60oC(de-rating) |
| Altitude |
|
Operating5000m,Non-Operating 16000m |
| Protection class |
|
IP21 |
| Battery temperature sensor |
|
BTS-optional remote battery temperature senser for increased charging precision |
| Terminal size(fine/single wire) |
|
#8 AWG |
| PV inverter battery priority |
|
|
| Input Voltage Waveform |
|
Sinusoidal (utility or generator) |
| Nominal Input Voltage |
|
230Vac |
| Low Line Disconnect |
|
155Vac±4% |
| High Line Diconnect |
|
265Vac±4% |
| Max AC Input Voltage |
|
270Vrms |
| Nominal Input Frequency |
|
50Hz/ 60Hz (Auto detection) |
| Over-Load Protection |
|
Circuit breaker |
| Output Short Circuit Protection |
|
Circuit breaker |
| Efficiency (Line Mode) |
|
>95% |
| Transfer Switch Rating |
|
30A |
| Transfer Time(Ac to Dc) |
|
20ms (typical) |
| Output Voltage Waveform |
|
Sine wave |
| Rated Output Power (W) |
|
1500W |
| Power Factor |
|
1 |
| Nominal Output Voltage (V) |
|
230Vac |
| Output Voltage Regulation |
|
±10%rms |
| Nominal Efficiency |
|
>80% |
| Bypass |
|
Optional |
| AC Charger |
|
Optional |
| Charge Current Regulation |
|
±5A |
| Battery initial voltage |
|
0-15.7 Vdc /31.4/59.1 Vdc(can operate with 0V battery) |
| Communication |
|
RJ11 (Used for factory testing. No customer interface available) |
| Safety Certification |
|
CE(EN60950) |
| EMI Classification |
|
EN50091-2, CLASS A |
| Operating Temperature Range |
|
0oC to 40oC |
| Storage temperature |
|
-15oC ~ 60oC |
| Operation humidity |
|
5% to 95% |
| Audible Noise |
|
60dB max |
| Cooling |
|
Forced air, variable speed fan |